Skip to content

Industrial Compressors with Charge Air Cooling

Overview

CAPA Industrial Compressors with Charge Cooling are designed to produce air for burner aeration in the petroleum industry. The Compressor is suitable for high flow, low pressure applications.

Please contact us for pricing on this product.

View General Information (PDF, 1.4mb)

Overview
Performance1500cfm @ 5.5psi
Discharge Temperature no more than 15°C above Ambient
Support Ambient Temperature up to 50°C
Enclosure Dimensions2200mm x 1200mm x 1400mm (L x W x H)
Enclosure MaterialGalvanised Steel Frame and Roof, Aluminium Panels
Weight1400kg
CompressorVortron Z80
Fan800mm
Fan Air Cooler2x Cores at 450mm x 900mm x 100mm (W x H x D)
Other FeaturesVFD Controllers for Compressor and Fan

Compressor Information

A Vortron Z80 Compressor is driven by a 37kW Motor. The Motor is controlled by a VFD. The Vortron Compressor is mounted in an enclosed Air Box with an Air Filter mounted on the end of the Enclosure.

NOTE: VFD’s are mounted in the enclosure for transportation purposes only.

Compressor Information
CompressorVortron Z80
Compressor Inlet5” Compressor Inlet, 6” Pipe with Mesh Screen
Compressor Discharge4” Compressor Outlet, 4” Pipework, One Way Valve
Motor37kW controlled by VFD
Compressor DriveVortron Mounting Plate, 14-Rib Drive, Automatic Tensioner
Filter Size1100mm x 1100mm x 90mm (W x H x D)

Air Cooler Information

The Air Cooler Assembly has Inlets on both ends, with the discharge in the centre. A fan is mounted to the air cooler.

Air Cooler Information
Core DimensionsTwo Cores at 450mm x 900mm x 100mm (W x H x D)
Core TypeOpen Tube Design, 9 Fins per Inch
Air Cooler Inlet2x 4” Inlets
Air Cooler Outlet8” Outlet, tapered down to 6”

Air Cooler Fan Information

Air Cooler Fan pushes air through the cooler cores. Air enters from the end of the enclosure and exits on the air cooler discharge side of the enclosure.

Air Cooler Fan Information
Fan Dimensions900mm x 900mm x 750mm (W x H x D)
Air Cooler Fan Size800mm
Fan Motor18.5kW controlled by VFD